Starboard genset raw-water impeller renewed
Completed 2026-09-02
Equipment: Starboard generator (Kohler 99EFOZDJ)
Stbd genset running warm on the last leg. Pulled the raw-water pump — impeller had shed three vanes. Fitted new impeller + cover gasket, cleared the debris from the heat-exchanger inlet, ran up to temp: steady. Photo of the failed impeller on file.
Parts used: Kohler impeller kit
Comments & history